66 Extreme Networks BlackDiamond 10K-Series Switch Installation Guide
BlackDiamond 10808 Switch Power Supplies and Power Supply Controllers
Figure 19: Sliding the power supply into the power bay
The AC input is located on the front of the BlackDiamond 10808 switch directly under each power
supply bay. The front of the power supply has a handle with a cam lever mechanism for both insertion
and removal of the power supply. The front panel also provides status LEDs. Table 16 describes the LED
behavior on the AC power supplies.
Table 16: AC power supply LEDs
LED Color Indicates
Power (PWR) Blinking Green
Solid Green
Off
Power is present and standby output is on.
AC power is present and power supply is operating normally.
There is no power present.
Predictive
Failure
Blinking Amber
Off
A fan has slowed down and is about to fail.
The fans and power supply are operating normally.
Fail Blinking Amber
Solid Amber
Off
There is a current limit on 48 VCD output.
The power supply has failed, or there is no AC power to this
power supply.