Connector Pinouts
BlackDiamond 12800 Series Switches Hardware Installation Guide
153
Connector Pinouts
Table 30 describes the pinouts for a DB-9 console plug connector.
Figure 87 shows the pinouts for a 9-pin to 25-pin (RS-232) null-modem cable.
Table 29: DC PS Model #65022 (325 W DC PSU)
For the BlackDiamond 12802 switch
Minimum configuration 2 power supplies
Full configuration 4 power supplies
Input Nominal input voltage: –48 V , –60 V , 15 A maximum
Operational voltage range: –40 V to –72 V
Maximum input amperages:
10 A @ –40 V (low-line)
8 A @ –48 V
7 A @ –60 V (high-line)
Maximum in-rush current: 8 A
Input circuit protection: 15 A
Wire harness provided by Extreme Networks with each power supply.
Extreme part number 4340-00028
Minimum wire size: 14 AWG (1.3 mm
2
) copper stranded
(pre-approved cord set for county of use)
Connector: Molex connector PN 42816-0312
Connector pins: Molex connector pins PN 42815-0032
Output DC Output:
48 V , 6 A/ 12 V
2.5 A/7 VSB 0.75 A
Output power (W): 325 W
Operating conditions Operating temperature: 0° C to 40° C
Storage temperature: –40° C to 70° C
Operating humidity: 10% to 90% relative humidity, non-condensing
Operational shock: 30 m/s
2
(3 g)
Table 30: Pinouts for the DB-9 Console Connector
Function Pin Number Direction
DCD (data carrier detect) 1 In
RXD (receive data) 2 In
TXD (transmit data) 3 Out
DTR (data terminal ready) 4 Out
GND (ground) 5 -
DSR (data set ready) 6 In
RTS (request to send) 7 Out
CTS (clear to send) 8 In
Page view 152